1.
|
Clear description of the referenced document:
|
|
|
2.
|
Status of approval:
|
|
White paper specification approved 2013-04-30.
|
3.
|
Justification for the specific reference:
|
|
The Bluetooth Personal Health Devices Transcoding White Paper, v1.4, is needed to allow device inter-connectivity within the Continua Design Guidelines personal area network architecture. This specification defines a short-range communications system intended to replace the cable(s) connecting portable and/or fixed electronic devices for Bluetooth low energy sensors.
|
4.
|
Current information, if any, about IPR issues:
|
|
N/A.
|
5.
|
Other useful information describing the "Quality" of the document:
|
|
Specification approved 2013-04-30 and many qualified devices implementing this version of the specification exist. Even though this s titled a "white paper" it defines specific configuration and parameteres necessary for interoperable operation of devices.
|
6.
|
The degree of stability or maturity of the document:
|
|
Specification approved 2013-04-30 and many qualified devices implementing this version of the specification exist.
|
7.
|
Relationship with other existing or emerging documents:
|
|
See item 8 below and specific reference [1] and [17]. This specification utilized the modeling of a blood pressure devices medical system based on the domain information model defined within reference [1] and [17].
|
8.
|
Any explicit references within that referenced document should also be listed:
|
|
[1] ISO/IEEE Std 11073-20601™- 2008 Health Informatics - Personal Health Device Communication - Application Profile - Optimized Exchange Protocol - version 1.0.This also includes ISO/IEEE Std 11073-20601a™-2010 – Amendment 1/
[2] Device Information Service V10r00/
[3] Characteristic descriptions are accessible via the Bluetooth SIG Assigned Numbers and the Formats section at Bluetooth SIG Developer Portal./
[4] ISO/IEEE Std 11073-10408™-2008 Standard for Health informatics - Personal health device communication - Device specialization - Thermometer/
[5] Health Thermometer Service V10r00/
[6] Continua Design Guidelines 2010 (version 1.5)/
[7] IEEE Std 11073-10406™-2011 Standard for Health informatics - Personal health device communication - Device specialization - Basic Electrocardiograph (ECG) (1 to 3-lead ECG)/
[8] Heart Rate Service V10r00/
[9] Blood Pressure Service V10r00/
[10] IEEE Std 11073-10407™-2008 Standard for Health informatics – Personal health device communication – Device specialization – Blood Pressure Monitor/
[11] IEEE Std 11073-10417™-2011 Standard for Health informatics – Personal health device communication – Device specialization – Glucose meter/
[12] Glucose Service V10r00/
[13] Bluetooth Core Specification v4.0 or later/
[14] Current Time Service V10r00/
[15] ISO/IEEE Std 11073-10441™-2008 Standard for Health Informatics – Personal health device communication – Device specialization – Cardiovascular fitness and activity monitor/
[16] Description of the Current Time Characteristic format in the Bluetooth SIG developer site./
[17] Specification of Regulatory Certification Data List at ISO/IEEE Std 11073-20601a-2010, sections 6.3.2.3 (MDS class attributes) and A.11.2 (MDS-related data types)./
[18] Patient Care Device (PCD) Technical Framework at the IHE site.
|
9.
|
Qualification of
Bluetooth:
|
|
Bluetooth SIG meets the qualifying criteria for normative referencing as per Recommendation ITU-T A.5.
|
10.
|
Other (for any supplementary information):
|
|
N/A
|