-- Module M3100ASN1TypeModule4 (M.3100:08/2004)
-- See also the README file
-- See also the index of all ASN.1 assignments needed in this document
M3100ASN1TypeModule4 {itu-t recommendation m gnm(3100) informationModel(0)
asn1Modules(2) asn1Module4(3)} DEFINITIONS IMPLICIT TAGS ::=
BEGIN
-- EXPORTS everything
IMPORTS
ObjectInstance
FROM CMIP-1 {joint-iso-itu-t ms(9) cmip(1) modules(0) protocol(3)}
EventTime
FROM Attribute-ASN1Module {joint-iso-itu-t ms(9) smi(3) part2(2)
asn1Module(2) 1}
AdditionalInformation, AlarmStatus, PerceivedSeverity, ProbableCause
FROM Attribute-ASN1Module {joint-iso-itu-t ms(9) smi(3) part2(2)
asn1Module(2) 1};
-- Begining of Amd.7
AlarmReportingControlList ::= SET OF AlarmReportingControl
AlarmReportingControl ::= SEQUENCE {
controlledEntity ObjectInstance,
arcProbableCauseList SET OF ProbableCause, -- empty means all
arcState ArcState, -- the value alm(0) is not used
timeRemainingInARCState INTEGER OPTIONAL
} -- for TI or QI-CD
-- Note that an empty set of arcProbableCauseList means all probable causes.
-- Note that for the field arcState, the value alm(0) is not used.
-- Once an object enters the normal reporting mode (i.e., in the alm state),
-- the corresponding AlarmReportingControl entry will be
-- automatically removed the AlarmReportingControlList.
-- Note that the field timeRemainingInARCState is optional.
-- It is optionally applicable only when the arcState is either
-- (a) nalmQualifiedInhibit(2) and Count-Down is supported, or
-- (b) nalmTimedInhibit(4).
-- Also note that when setting up the ARC setting, this field can be used by the
-- managing system to override the default TI interval or CD interval.
-- End of Amd.7
AlarmingResumed ::= BOOLEAN -- TRUE implies alarm reporting is resumed
ArcAffectedObjectList ::= SET OF ObjectInstance
ArcAlarmDetail ::= SEQUENCE {
problem ProbableCause,
alarmStatus AlarmStatus,
perceivedSeverity PerceivedSeverity OPTIONAL, -- must be present unless <unassigned> (i.e. not an alarm)
eventTime EventTime OPTIONAL
}
ArcAlarmDetailSet ::= SET OF ArcAlarmDetail
ArcControlRequest ::= SEQUENCE {
time ArcTime DEFAULT noAdjustment:NULL,
newState ArcState,
additionalInfo AdditionalInformation OPTIONAL
}
ArcDefaultNALMCDInterval ::= ArcTime
ArcDefaultNALMTIInterval ::= ArcTime
ArcInterval ::= INTEGER(0..5940) -- minutes (max of 99 hours)
ArcProbableCauseList ::=
SET OF ProbableCause -- empty set means all object probable causes
ArcState ::= ENUMERATED {
alm(0), nalm(1), nalmQualifiedInhibit(2), nalmTimedInhibit(4)}
ArcQIStatus ::= ENUMERATED {
notApplicable(0), nalmNotReported(1), nalmCountDown(2)}
ArcTime ::= CHOICE {
noAdjustment [0] NULL,
time [1] ArcInterval -- minutes
}
NotSupportedProbableCause ::= SET OF ProbableCause
END