(Continuation of Question 13/5) Motivation
Protection against overvoltages and overcurrents of telecommunication
installation and equipment is achieved with adequate resistibility level of both
equipment and lines insulation and proper installation of suitable protective
devices. Changes have occurred in the resistibility requirements and protective
devices technology.
These changes require studies to ensure that the recommendations on
protective devices fit the needs of the operators and the user of
telecommunication networks.
The following Recommendations, in force at the time of approval of this
Question, fall under its responsibility:
- K.11, K.12, K.28, K.30, K.36, K.55, K.65 and K.69.
Question
The objective of this question is to establish Recommendations for
specifications, test methods and principles of application for protective
components and assemblies intended to mitigate effects of lightning, power
induction, ESD, fast transients and power contacts that may cause permanent
damage. These protective components and assemblies are related to both
telecommunication and power supply circuits of telecommunication equipment.
Study items to be considered include, but are not limited to:
- The limits for minimum and maximum d.c. sparkover voltage, and maximum
impulse sparkover voltage before and after life tests;
- Coordination of overcurrent protection components in the MDF and the
equipment;
- The introduction of solid-state overcurrent protection components;
- Coordination of overvoltage and overcurrent protection;
- Considerations intended to facilitate the selection of most effective
protection method (e.g. source and intensity of overvoltages and overcurrents).
Tasks
Tasks include, but are not limited to:
- New Recommendations on the application of new protection elements and/or
assemblies;
- New Recommendations on the basis of the following criteria:
- Basic requirements, based on K.11 and K.36;
- Product requirements, based on K.12, K.28, K.30, K.55 and K.65.
- New Recommendation on Self restoring overcurrent protectors;
- New Recommendation on Characteristics of metal oxide varistors for the
protection of telecommunications installations;
- Maintenance of the existing Recommendations under the responsibility of the
Question;
- Possible revision of Volume VIII of the Directives.
An up-to-date status of work under this Question is contained in the SG 5 Work
Program (use URL as shown in the table below).
Relationships
Recommendations:
Questions:
Study Groups:
Standardization bodies:
- IEC SC 37A, IEC SC 37B, IEC TC 64, IEC TC 81, CENELEC TC 81X, IEC SC 77B
|